Bộ chuyển tín hiệu đa thông số Model: OPTISENS MAC 100

Bộ chuyển tín hiệu đa thông số
Model: OPTISENS MAC 100
Hãng sản xuất: Krohne – Đức
Tham khảo tại:  http://vn.krohne.com
Kết quả hình ảnh cho OPTISENS MAC 100 Krohne

Product Features:
Highlights:
-     KROHNE General Device Concept (GDC)
-     Standardised operating concept from flow and level extended to analytical parameters
-     Up to 2 sensor inputs + temperature input
-     3 current outputs
-     Large graphic display
-     Robust aluminium housing (IP66)
-     Build-in temperature and pH compensation
-     Calibration logbook
-     HART (in preparation)
Industries:
-       Water / Waste water
-       Power industry
-       Process industry
-       Food and Beverages

Specifications:
Measuring system:
-       Measuring principle: Depends on the used sensor(s)
-       Application range: Continuous measurement of parameters in liquid analysis applications.
-       Measuring range: Depends on the used sensor(s)
Design:
-       Construction A typical measuring system consists of:
§  MAC 100 multiparameter signal converter
§  1 (or up to 2) sensors of the OPTISENS series
§  Sensor cable
§  MAA mounting assemblies
-       Option The device is available as a one channel (one signal input) or a two channel version (two signal inputs). You can connect one sensor to the one channel version and up to two sensors to the two channel version.
-       Sensors For further information refer to the  manual of the relevant sensor.
-       Also note the table with the sensor input combinations on page 7.
Display and User interface:
-       Graphic display: LC display, backlit white 128 x 64 pixels
Note: ambient temperatures below -25°C / -13°F" may affect the readability of the display!
-       Operating elements: 4 push buttons for operator control of the signal converter without opening the housing.
-       Operating menu:
§  The operation menu consists of the measuring mode and the menu mode:
§  Measuring mode: 4 pages (first and second measuring page with measuring results, status message and trend diagram).
§  Menu mode: variety of main and submenus that allow to customise the device according to the demands of the measuring point.
-       Operating and display languages: English, German,  (others on request)
-       Units: Metric, British and US units selectable as required from lists
Measuring accuracy:
-       Reference conditions:
§  Temperature: 20°C /  68°F
§  Pressure: 1 bar / 14.5 psi
-       Maximum measuring error: For further information refer to the  manual of the relevant sensor.
-       Repeatability: For further information refer to the  manual of the relevant sensor.
-       Resolution: Temperature: 0.1°C /  0.1°F". For further information refer to the  manual of the relevant sensor.
-       Long-term stability: 24 hours: tested within accuracy definition
-       Temperature drift: Tested within accuracy definition
-       Cable length variation: Tested within accuracy definition
Operating conditions:
Temperature:
-       Ambient: -15...+55°C / +5...131°F
Note: the manufacturer strongly recommends to protect the signal converter from external heat sources such as direct sunlight as higher temperatures reduce the life cycle of all electronic components.
-       Storage: -40...+70°C / -40...+158°F
Other conditions:
-       Humidity (ambient): Max. 90% at 40°C / 104°F
-       Pressure: For information about the process pressure of the used sensor(s) refer to the relevant sensor documentation!
-       Protection category acc. to IEC 529 / EN 60529: IP66/67 (acc. to NEMA 4/4X)
Installation conditions:
-       Installation: Only wall mounting is possible, always assure a vertical mounting orientation!
-       Dimensions and weights: For detailed information see chapter "Dimensions and weights".
Materials:
-       Signal converter: housing Die-cast aluminium (polyurethane coated)
-       Measuring sensor: For housing materials, process connections, liners, grounding electrodes and gaskets, see the technical documentation for the measuring sensor.
Electrical connections:
-       General: Electrical connection is carried out in conformity with the VDE 0100 directive "Regulations for electrical power installations with line voltages up to 1000 V" or equivalent national regulations.
-       Voltage: 100…230 VAC (-15% / +10%), 50/60 Hz; 240 VAC + 5% is included in the tolerance range. 
-       Power consumption: 4.2 W, 10 VA at 230 VAC
-       Fuse: 0.8 AT/250V (high breaking capacity ), 5 x 20 mm / 0.2 x 0.8"
-       Line frequencies: 50/60 Hz
-       Power rating: 22 VA (maximum)
-       Inrush current IN, eff = 97 mA,  t15 = 1.5 ms,  tPeak = 200 µs, Ipeak = 22.6 A
-       Cable entries:
§ 1 channel: 4 x M20
§ 2 channels (separate temperature sensor): 3 x M20, double PG two times 5 mm / 0.20" screwed connection for sensor cables
§ 2 channels (integrated temperature sensor): 3 x M20, double PG two times 8 mm / 0.31" screwed connection for sensor cables
Inputs and outputs:
-       General:  All in- and outputs are electrically isolated from each other and from all other circuits. All operating data and output values can be adjusted.
-       Description of used abbreviations: Uext = external voltage;  RL= load + resistance; Uo = terminal voltage; Inom = nominal current
Inputs:
-       Sensor inputs: Up to 2, depending on the version. For further information refer to the  manual of the relevant sensor.
-       Control input:
§  Passive, not polarity sensitive, Uext, max ≤ 32 VDC, Inom = 6.5 mA  with  Uext= 24 VDC, Inom = 8.2 mA  with  Uext= 32 VDC
§  Switching point for identifying "contact open or closed": contact open ("off") at U0 ≤2.5 V with Inom = 0.4 mA, contact closed ("on") at U0 ≥ 8 V with Inom = 2.8 mA
Outputs:
Current outputs:
-       Three isolated outputs (4...20 mA), all galvanic isolated, errors signals 3.25 mA and
-       22 mA, active mode
-       Output data: depending on sensor
-       Operating data: Uint, nom = 15 VDC, I = 0(4)...22 mA, Imax ≤ 22 mA, RL≤ 550 Ω
Relay outputs:
-       Three electro-mechanical relays that can work as alarm relays or limit switches
-       Possible conditions: NO (normally open) or NC (normally closed)
-       Contact ratings:
§ Relays for low voltages: U ≤ 30 VDC, I ≤ 1 A, resistive load (PELV / SELV) or U ≤ 50 VAC, I ≤ 4 A, resistive load (PELV / SELV)
§ Relays for high voltages: U = 100...230 VAC, I ≤ 4 A, max. 1000 VA resistive load
HART: In preparation
Approvals and certifications:
-       CE: This device fulfils the statutory requirements of the EC directives. The
-       manufacturer certifies successful testing of the product by applying the CE mark.
-       Shock resistance: IEC 68-2-3
-       Electromagnetic compatibility: 2004/108/EC in conjunction with EN 61326-1 (A1, A2)
-       Low Voltage Directive: Safety requirements for electrical equipment for measurement, control, and laboratory use in accordance with EN 61010-1:2001.

Sensor input combinations:
Sensor type
Measured
parameter
Measuring
principle
Signal converter
Input A
Input B
PAS 1000 pH
pH value
Potentiometric
X
X
PAS 1000 ORP
ORP value
Potentiometric
X
X
AAS 1000 Cl2
Free chlorine
Amperometric
X

AAS 1000 ClO2
 (1)
Chlorine dioxide
Amperometric
X

AAS 1000 H2O2
 (1)
Hydrogen peroxide
Amperometric
X

AAS 1000 O3
 (1)
Ozone
Amperometric
X

AAS 1000 DO
(1)
Dissolved oxygen
Amperometric
X
X
CAS 1000
 (1)
Conductivity /
specific resistance
Conductive (2-
pole)
X
X
IAS 1000
(1)
Conductivity
Inductive
X
X
(1) In preparation